        CEC certification is an appliance efficiency regulation (Appliance Efficiency Regulation) implemented by the California Energy Commission in December 30, 2005. The purpose of implementing this regulation is to improve the efficiency of electricity products, save energy, reduce gas emissions and the greenhouse effect.

         image.png

        Significance of CEC certification

        As more and more electronic products appear in daily life, "saving energy" will become an urgent problem that everyone in the 21st century must face. The California Energy Commission (CEC) will implement a new mandatory standard for the energy efficiency of AC-DC and AC-AC external power supplies on July 1, 2006. By then, almost all electronic products will Suffered an impact.

        The standard will cover all products that use external power supplies (such as chargers and adapters), including mobile phones, home wireless phones, portable music players, handheld game consoles, toys, etc., and require these products to be in standby and use. Use energy in a more efficient way.

        This means that after mid-2006, all transformers, external power supplies, adapters, and chargers used in the United States and sold to the United States must change their design.

        In addition to saving energy, the new CEC regulations will also have a major impact on environmental protection. According to the company's statistics, if all of California's external power supplies can comply with the new standard, California will be able to reduce carbon dioxide emissions by more than 360,000 tons per year, which is equivalent to the annual emissions of 60,000 cars.

        The regulation stipulates that electrical products must first meet the energy efficiency regulations of equipment when they are sold in California. The regulations stipulate energy efficiency index requirements, measurement methods, and phased implementation plans for 58 types of electrical products. According to the requirements of this regulation, electrical products must be tested by qualified laboratories in accordance with the corresponding regulations or standards of the United States and proved to meet the requirements before they can be sold in California.

        Applicable product range

        The standard will cover all products that use external power supplies (such as chargers and adapters), including mobile phones, home wireless phones, portable music players, handheld game consoles, toys, etc., and require these products to be in standby and use. Use energy in a more efficient way. The definition range of CEC's external power supply is: single-phase voltage input AC / DC or AC / AC external power adapter.

        Application information

        1. Product name: Provide the full name of the product

        2. Product model: list all product models, varieties or classification numbers that need to be tested

        3. The intended use of the product: such as homes, offices, factories, coal mines, ships, etc.

        4. Parts list: detail the components and models (classification number), ratings, and manufacturer's name of the product. For insulating materials, please provide the name of the raw material

        5. Electrical performance: For electronic and electrical products, provide point schematic diagram (circuit diagram), ingredient list, etc.

        6. Structural drawing: For most products, the structural drawing or exploded drawing of the product, ingredients list, etc.

        7. Product photos, instructions for use, safety matters or installation instructions, etc.

        Testing requirements

        Summary: The test adjustment, unless otherwise stated, is tested in accordance with the following test conditions.

        Test

        Instruments: Power measurement must be performed with a calibrated voltammeter or power analyzer. The instrument must be calibrated according to the IEC 62301 standard. When the test power is 0.5W, the error must be less than or equal to 2%. When the test power is less than 0.5W, the error must be less than 0.01W. The accuracy of the power test instrument must reach 0.01W or better. The test voltage and current errors must be less than or equal to 2%.

        Test room according to the requirements of IEC 62301, the air flow in the test room must be 0.5m / s or less, the ambient temperature must be controlled within the range of 23 ℃ ± 5 ℃, the sample must be placed on the test bench without heat conduction On the test. For products used outdoors, if there are additional test requirements, they must be stated in the report.

        Test voltage According to the requirements of IEC 62301, the fluctuation range of the test voltage cannot exceed ± 1% of the specified test voltage and ± 1% of the specified test frequency. If the input voltage on the nameplate is wide, the test voltage is 115V / 60Hz and 230V / 50Hz. If the nameplate indicates a single voltage input, the test voltage is one of the above two test voltages.

        Judgment of results The California Energy Efficiency Law requires that from July 1, 2006, all external power supplies exported to California must meet the average energy efficiency requirements and no-load power requirements in the following table (see Table 1)

        From January 1, 2008, all external power supplies exported to California must meet the new average energy efficiency regulations and no-load power requirements in the following table TABLE2 (see Table 2)

        All tests must take into account the load conditions of 100%, 75%, 50%, and 25% of the output current marked on the nameplate (note: the error range of the load here cannot exceed ± 2%), and record their input power, Input current, power factor, output voltage, and THD (total harmonic distortion), then follow

        Energy efficiency = (output voltage × output current) / input power

        To calculate the current energy efficiency value, and then average the energy efficiency values measured under the four load conditions of 100%, 75%, 50%, and 25% to obtain the average energy efficiency value. In addition, you must also test the load with an output current of 0% The input power value, the average energy efficiency value and the no-load power value obtained by the above test are determined according to the limit requirements of TABLE1 and TABLE2 to determine which energy efficiency mark is met.

        other

        Certification cycle

        Regular 3-4 weeks, can be expedited


        Online consultation

        Online consultation

        Recommend
        • Label printer ANATEL certification

          Label printer ANATEL certification

          Label printers entering the Brazilian market, ANATEL certification is an essential passport! It is the recognition of the Brazilian Telecommunications Authority for the safety and compliance of electronic products, without which products cannot be legally sold.

        • Label printer SRRC certification

          Label printer SRRC certification

          SRRC certification is not only a guarantee of product compliance, but also a key to opening up the market.

        • Label printer FCC ID authentication

          Label printer FCC ID authentication

          FCC ID certification is a mandatory certification for electronic products by the Federal Communications Commission (FCC) in the United States, and it is essential for label printers to obtain this certification.

        California Energy Efficiency CEC Certification

        CEC certification is an appliance efficiency regulation (Appliance Efficiency Regulation) implemented by the California Energy Commission in December 30, 2005. The purpose of implementing this regulation is to improve the efficiency of electricity products, save energy, reduce gas emissions and the greenhouse effect.

        Get a quote
        主站蜘蛛池模板: 色欲av无码一区二区人妻| 国产午夜三级一区二区三| 黄色大全免费看国产精品| 又黄又爽又色视频免费| 中文字幕人妻无码一区二区三区 | 国内精品自线在拍| 欧美日本激情| 18禁裸乳无遮挡啪啪无码免费 | 毛片久久网站小视频| 久久精品国产一区二区三 | 无遮无挡爽爽免费视频| 中文字幕亚洲人妻一区| 国产成人av一区二区三区不卡| 加勒比无码人妻东京热| 国产精品人妻中文字幕| 色天天天综合网色天天| 国产午夜福利不卡在线观看| 国产a网站| 亚洲精品国产字幕久久麻豆| 中文字幕日韩精品亚洲一区| 国产成人AV男人的天堂| 亚洲国产av无码综合原创国产| 国产一级精品在线免费看| 精品人妻日韩中文字幕| 精品免费看国产一区二区| 精品久久精品久久精品久久| 色综合天天综合天天综| 亚洲第一二三区日韩国产| 蜜桃av色偷偷av老熟女| 亚欧美闷骚院| 蓬溪县| 激情国产一区二区三区四| A毛片终身免费观看网站| 高清不卡一区二区三区| 精品国产一区二区三区性色| 欧美XXXX黑人又粗又长| 国产偷人妻精品一区二区在线| jizz国产免费观看| 国产精品论一区二区三区| 中国老太婆video| 在线a人片免费观看|