        IEC 60598-1: 2020 edition standard update instructions

        Author:中認聯(lián)科 time:2020-09-21 Ctr:3601

        IEC 60598-1:2020 luminaires. Part 1 of general requirements and tests was officially released on August 17, 2020. IEC 60598-1:2020 is the ninth edition released this time and will replace IEC 60598-1:2014+A1 : The 2017 version.

        image.png

        Compared with the previous version, the new version includes the following major technical changes:

        1. Add PELV and related requirements. Due to transient protection circuits and EMC reasons, the market has a strong demand for PELV circuits. Considering IEC TR 63139 (under development), where SELV appears in the standard, the addition of PELV related modifications involves Chapter 3, Chapter 4, Chapter 7, Chapter 8, Chapter 10, Appendix X, etc.;

        2. Modified Table 10.3 and Article 3.3.19 for high protection currents. According to the regulations stated in the manual of 3.3.19, the power supply current limit of 20A or more shall be added on the basis of the original applicable objects, that is, the applicable objects of this clause are Permanently connected lamps with a power supply current of more than 20A and a protective conductor current of more than 10 mA, and the corresponding limit in Table 10.3 is changed from 10 mA to 10 mA or in accordance with the manufacturer’s instructions;

        3. Article 3.3.26 adds the marking requirements for wall-mounted lamps within the reach of the arm, and requires additional instructions for fixing the cable to the wall;

        4. Article 3.2.27 adds requirements for constant light output function and programmable current output;

        5. Article 4.30 Non-user replaces the electric shock protection cover used for light source lamps;

        6. Article 4.24.2 Blu-ray hazards delete category 0 hazards;

        7. Article 5.2.16 adds the component standard IEC 61984 that the connector should comply with, as well as additional requirements such as polarity interchange, mechanical locking, protection against electric shock, short circuit protection, and cable clamping;

        8. Article 3.3.25 adds the requirements of cable UV protection;

        9. Article 4.34 requires lamps not to emit harmful electromagnetic fields and should comply with EMF IEC 62493;

        10. Updated the functional grounding and protective grounding and their requirements in the 1.2.73 standard, including adding definitions, adding the qualifiers of "function" or "protection" to "grounding" in the clauses; in Appendix G, adding The description of the disconnection of the functional ground (if separate) when measuring the protective conductor current is added, and the functional ground terminal or contact that can be touched should be regarded as an accessible part and tested when measuring the contact current;

        11. Article 4.35 puts forward the test requirements to prevent the fan blades driven by the motor for cooling in the lamps from being touched, and gives the exemption test conditions, such as low hardness, low speed and low power;

        12. Article 3.2.2 Modify the marking requirements of rated voltage, delete the situation that does not need to be marked with rated voltage, that is, all lamps must be marked with rated voltage in volts;

        13. In the provisions of Article 5.2.10, the provisions that meet the requirements of 5.2.10.4 can be used as an exception to the use of flexible cord holders. The additional 5.2.10.4 provides for exceptional conditions, including overcurrent protection devices. The highest short-circuit current reached does not exceed 2A, and the highest voltage of various Class III lamps, and the corresponding qualification test requirements;

        14. The measurement network in Appendix G for the measurement of contact current and protective conductor current is revised;

        15. Modified the contact voltage limit value of irregular DC voltage in 8.2.3c);

        16. Article 1.2.96 Luminaires (PoE) that rely on Ethernet power supply that meets IEC 62368-3 power supply are connected, involving definitions, structures, thermal tests and an appendix introducing PoE luminaires;

        17. Article 9 IP adds high pressure and high temperature water blowout protection IPX9 (80℃) and high pressure and low temperature water blowout protection IPX9 (15℃) and its test requirements;

        18. Amended Appendix D to introduce alternative thermal tests for lamps whose ta mark is higher than 25℃;

        19. In Article 0.2, 4.14.1 was added, and relevant requirements for rail-mounted luminaires were added, including definitions, and rail-mounted luminaires were added to 4.14.1 test objects, and a requirement was added in Chapter 4, that is, rail-mounted luminaires It shall be tested in accordance with IEC 60570 Annex A;

        20. The test method of 10.2.2 to increase the electrical strength of DC lamps is modified;

        21. Amended Appendix D and added the temperature limit to Table 12.1 and Table 12.3. For lamps marked with F, the covering layer is changed to directly contact the lamp instead of covering the outside of the box before;

        22. The minimum torque of the metal gland test in Table 4.2 is reduced from 6.25 Nm to 4 Nm;

        23. Amend the requirements for protective impedance devices (4.10.4) in Section 4.10.4 and Appendix U, and modify the quantity requirements of Y1 and Y2 to be expressed in tables, and according to the power supply voltage, impulse withstand category, and insulation of the jumper And the number of capacitors required by the capacitor type (Y1, Y2 or Y4). The relevant amendments involve Chapter 4 and Appendix U;

        24. Amend the second paragraph of 5.2.14 to modify the category III plugs used in lamps and lanterns, in the original requirement that category III plugs cannot be connected to the grid power socket, "cannot be connected" is changed to "cannot be electrically connected", and The test method is added, and the relevant modification involves Chapter 5 and Chapter 4.


        Related Articles
        • Don't let KC certification hold you back! ZRLK teaches you to get your certificate efficiently

        • Eu RHOS Certification: The "Green Pass" for Enterprises to Export to the EU

        • Energy conservation and compliance both online! Analysis of the Practical Value of CEC Certification

        • A Comprehensive Guide to DOE Certification: What's the First Step to Compliance When Exporting Electronic and Electrical Appliances to the United States?

        Follow Us
        主站蜘蛛池模板: 久久精品国产亚洲av忘忧草18| 亚洲精品一区二区三区小| 中文天堂资源| 国产一区二区不卡在线看| 国产成人精品无码播放| 亚亚洲视频一区二区三区| 亚洲精品第一区二区在线| 久久综合久久美利坚合众国| 色达县| 国产精品午夜福利小视频| 夜爽8888视频在线观看| 日韩有码中文字幕第一页| 国产精品亚洲mnbav网站| 人妻蜜臀久久av不卡| 国产午夜福利视频在线| 国产影片AV级毛片特别刺激| 色噜噜狠狠成人综合| 亚洲免费成人av一区| 美女扒开奶罩露出奶头视频网站| 国产精品久久国产三级国不卡顿| 欧美性色黄大片| 精品无码国产日韩制服丝袜| 九九热精品在线视频免费| 无码人妻精品一区二区三区下载| 精品亚洲一区二区三区在线播放| 深夜免费av在线观看| 精品国产一区二区三区大| 日本一本无道码日韩精品| 四虎影视一区二区精品| 久久精品无码一区二区三区| 丁香婷婷无码不卡在线| 日韩成av在线免费观看| 国产资源精品中文字幕| 自拍偷自拍亚洲精品熟妇人 | 国产成人av一区二区三| 裸身美女无遮挡永久免费视频| 无码av岛国片在线播放| 国产精品无码久久久久AV| 绝顶丰满少妇av无码| 国产精品欧美亚洲韩国日本久久| 九九热精品在线观看|